• Darkroom 10m EMC Anechoic Chamber Electromagnetic Compatibility Room
  • Darkroom 10m EMC Anechoic Chamber Electromagnetic Compatibility Room
  • Darkroom 10m EMC Anechoic Chamber Electromagnetic Compatibility Room
  • Darkroom 10m EMC Anechoic Chamber Electromagnetic Compatibility Room
Good price Darkroom 10m EMC Anechoic Chamber Electromagnetic Compatibility Room online

Darkroom 10m EMC Anechoic Chamber Electromagnetic Compatibility Room

Product Details:

Place of Origin: China
Brand Name: Sinuo
Certification: Calibration Certificate (Cost Additional)
Model Number: SN661-10M

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: Customized
Packaging Details: Export package
Delivery Time: 30 days
Payment Terms: T/T
Supply Ability: 1 set/month
Contact Now

Detail Information

Applied Standard: IEC 61000 Series, Etc. Chamber Dimensions: 24.0m X 17.0m X 9.0m
Frequency Rang: Can Be Customized Test Distance: 10m
NSA Maximum Deviation: ±3.5 DB Test Static Zone: Straight 5.0m / Height 2.0m
Maximum VSWR: ≦5.5dB Warranty Term: One Year
High Light:

emc anechoic chamber

,

Darkroom emc anechoic chamber

,

Electromagnetic Compatibility Room 10m emc chamber

Product Description

 
 

10m EMC Darkroom Anechoic Chamber Electromagnetic Compatibility Room

 
Complied Standards & Clauses


 

CISPR 11  "industrial, scientific and medical equipment radio disturbance characteristics - Limits and methods of measurement."

 

CISPR 14-1/GB 4343.1 "household electrical electromagnetic, electric tools and similar apparatus compatible Part 1: emission"

 

CISPR 14-2/GB 4343.2 "household electrical electromagnetic, electric tools and similar apparatus compatible with the requirements of Part 2: Immunity"

 

IEC 61000-3-2/GB 17625.1  "Electromagnetic compatibility limits for harmonic current emissions (equipment input current ≤16A)"

 

IEC 61000-3-3/GB 17625.2  "Electromagnetic compatibility limits the voltage variation produced with rated current ≤16A and unconditional access of the device in public low-voltage power supply system, voltage fluctuations and flicker limits"

 

IEC 61000-4-3 / GB T17626.3 “Electromagnetic compatibility (EMC)–Part 4: Testing and measurement techniques Section3– Radiated, radio-frequency, electromagnetic field immunity test”
 
EN 55022 “Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement”
 
CISPR 22 B (30MHz-1GHz) “Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement”
 
CISPR 16-2-3 (1GHz-18GHz) “Specification for radio disturbance and immunity measuring apparatus and methods- Part 2-3 “Method of measurement of disturbances and immunity- Radiated disturbance measurements”
 

.......


Equipment Overview


Application: Simulating open field test conditions, primarily for radiated interference (EMI) and radiation sensitivity (EMS) measurements.
 
Test Principle: Also named EMC darkroom, belonging to the semi-anechoic darkroom (Semi-Anechoic chamber, referred to as SAC), an simulation open field mainly in the static zone, shielding effectiveness, normalized site attenuation, field uniformity, site voltage standing wave ratio and other parameters performance
 
Structure: The EMC darkroom generally consists of the main steel structure, shielding body, wave filter, air conditioning ventilated waveguides (divided into the wind inlet and outlet waveguides), shielding door, absorbing materials, lightings, interface boards, elevated floor, turntable, antenna tower, controller, monitoring systems, smoke alarm systems, and power distribution systems.

 

Advantages: 10m method anechoic chamber simulates the open field environment better and is the best choice for large equipment. In the shielded room ceiling and four wall stickers on the absorbing material, the ground absorbing material using movable laying
For RF immunity and emission testing, suitable for larger products. 10m test distance with 3m or more quiet area, the darkroom to meet the FCC, CE and VCCI on the 10-meter darkroom certification and testing requirements.

Darkroom 10m EMC Anechoic Chamber Electromagnetic Compatibility Room 0
 

Technical Parameters


 

Dimensions
(length * width * height)

24.0m x 17.0m x 9.0m
Frequency Range 26MHz ~ 18GHz (optional to 40GHz)
Test Distance 10 m
Radiation Emission Test

Full compliance with EN 55022 and CISPR 22 Class B requirements (30MHz-1GHz)
Full compliance with CISPR 16-2-3 requirements (1GHz-18GHz)
Radiated immunity test

Radiated Immunity Test Full compliance with IEC / EN 61000-4-3 standard
NSA maximum deviation

±3.5 dB (meet CISPR 16-1-4requirement)

Maximum VSWR

≦5.5dB(meet CISPR 16-1-4 requirement)

Test Static Zone Straight 5.0m / height 2.0m
Even Field Size 1.5m x 1.5m
Max. Deviation 75% of the 16 measurement points satisfy 0dB / + 6dB
Schematic Diagram Darkroom 10m EMC Anechoic Chamber Electromagnetic Compatibility Room 1
 