Brand Name: | Sinuo |
Model Number: | SN883-X65 |
MOQ: | 1 |
Price: | Customized |
Payment Terms: | T/T |
Supply Ability: | 10 sets/month |
Water Cooling Xenon-Arc Lamp Exposure Environmental Test Chamber
Complied Standards & Clauses
SAE J2412: "(R) Accelerated Exposure of Automotive Interior Trim Components Using a Controlled Irradiance Xenon-Arc Apparatus"
SAE J1545: "(R) Instrumental Color Difference Measurement for Exterior Finishes, Textiles and Colored Trim"
IEC60068-2-5 “Environmental testing -Part 2-5: Tests-Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing, IDT”
AATCCM16 “Colorfastness to Light: Xenon-Arc”
ASTM-D4459 “Standard Practice for Xenon-Arc Exposure of Plastic Intended for Indoor Applications ”
GB/T16422.3 -2014 / ISO 4892-3:2006 “Plastics-Methods of exposure to laboratory light sources-Part 3: Fluorescent UV lamps”
Equipment Overview
The aging test is carried out by exposing the material of the samples (which including but not limited to automotive, coatings, rubber, plastics, pigments, adhesives, fabrics, aerospace, shipbuilding, electronics, packaging, etc.) to the illumination and heat radiation of the xenon arc lamp, to evaluate the light and weather resistance of some materials under the action of high temperature light source.
Xenon arc lamps simulate full sunlight spectrum to reproduce destructive light waves in different environments.
Technical Parameters
Model | SN883- X65 |
Dimensions | 124cm×114cm×202cm (W×D×H) |
Exposure area | 6500cm2/ About 65 standard samples (140mm×70mm) |
Light source | 6.5kW long arc water-cooled xenon lamp (imported from the United States Q-LAB) |
Light source life | About 2000h (based on irradiance 0.51W/m2 @340nm) |
Irradiance display band | 340nm, 420nm, 300~400nm optional |
Irradiance range |
0.3W/m2~1.1 W/m2(@340nm) 40 W/m2~120 W/m2(@300nm~400nm) |
Sample temperature |
Blackboard temperature: 40℃~110℃ Black mark temperature:40℃~120℃ |
Temperature in the chamber | 38℃~80℃ |
Humidity in the chamber |
When illuminated: 30%RH~75%RH (related to temperature) In the dark: up to 100%RH |
Test Conditions |
Free combination of light, darkness and water spray Note: the water spray can be performed or not, if water spray is not used as per IEC 62368-1 Annex C.2.4, operator can set the spray time to be “0”. |
Supported test standards |
Conforms to SAE J2412, SAE J2527, ASTMG 155ISO 105-B02, ISO 105-B04, ISO 105-B06, ISO 4892-2-A, ISO 11341-1, GB/T 16422-2, GB/T 1865
With 4 custom methods, users can set test parameters by themselves to meet most common standard requirements. |
Drum sample holder | |
The rotating drum sample holder can ensure the excellent irradiance uniformity of the upper, middle, and lower samples while taking into account the sample volume. In addition, the sample continuously rotates around the lamp tube with the sample holder to further ensure uniform and stable irradiance, sample surface temperature, and water spray. |
|
Control system | |
HMI |
Comprehensive and easy-to-use human-machine interface (Will be in English)
|
Main controller | Adopting the American GE company PLC, the control is accurate, stable and reliable. |
Data logging and export | Automatic recording of equipment operating status and various test parameters, users can export data for a specified period of time as needed. |
Safety protection function | |
Overcurrent protection Cooling water high temperature protection Low cooling water flow alarm protection |
|
Use conditions | |
Power source | AC 380V, 60Hz, three-phase five-wire (including ground wire) |
Water source | Tap water: 0.14~0.3 MPa Laboratory secondary water: 0.08~0.15 MPa Laboratory secondary water consumption: about 150 L/day |
Drain | The height of the drain from the ground: ≤15cm Drain interface diameter: ≥5cm |
Ambient temperature | 18℃~28℃ |
Environment humidity | 10%RH~85%RH |
Installation space | ≥280cm×300cm×280cm (W×D×H) |
Environmental conditions | Indoor, clean, less dust, flat ground, there is no corrosive, flammable, explosive gas, liquid, dust around |
Q: What about the exposure area?
A:6500cm2/ About 65 standard samples (140mm×70mm)
Q: What is the Radiation Intensity of Xenon?
A:0.3 W/m2~1.1 W/m2(@340nm)
40 W/m2~120 W/m2(@300nm~400nm)
SN883-X65 can reach 2 of levels which close to the sun level . Other domestic equipment is generally customized based on a certain standard and does not understand the irradiance requirements of different fields.
Q: What's the cooling system?
A:SN883-X65 can reach a higher power level to meet the needs of current and future test development. There is cooling water flowing between the filters, which can effectively reduce the infrared heat to the sample surface. And reduce the generation of ozone, increase the accurate matching with the external environment.
Cooling effect remark: water cooling is better than air cooling.