logo

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Temperature Humidity Test Chamber
Created with Pixso.

Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78

Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78

Brand Name: Sinuo
Model Number: SN881-1000L
MOQ: 1
Price: Customized
Payment Terms: T/T
Supply Ability: 1 sets/month
Detail Information
Place of Origin:
China
Certification:
Calibration Certificate (Cost Additional)
Inner Chamber Dimensions:
1000*1000*1000 Mm
Outer Chamber Dimensions:
1280*2150*2050 Mm
Humidity Range:
20%~98%RH
Temperature Range:
-70 °C ~+150°C
Humidity Fluctuation:
≤2.5%
Heating Rate:
≧2-3°C/min
Cooling Rate:
≧1°C/min
Temperature Fluctuation:
±0.5℃
Packaging Details:
Other
Supply Ability:
1 sets/month
Highlight:

1000L Temperature Humidity Chamber

,

Environmental Testing Temperature Humidity Chamber

,

IEC60068-2-78 Temperature Humidity Chamber

Product Description

 

 

Environmental Testing Temperature and Humidity Chamber 1000L IEC60068-2-78

 

 

Complied Standards & Clauses


 

IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”

IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

 

 

Equipment Overview


 

This test chamber is used for cold, heat, humidity, and dryness testing of raw materials and devices such as electronics, electricians, electrical appliances, plastics, etc. The purpose is to confirm the product's reliability of storage and transportation under high and low temperatures alternating heat and humidity.

 

Technical Parameters


 

Technical Parameters
Control & Operation PLC and touch screen intelligent control system

Chamber Size

 

Inner Size External Size
1000*1000*1000 mm 1280*2150*2050 mm
Temperature Range -70 °C ~+150°C
Humidity Range 20%~98%RH
Temperature fluctuation ±0.5℃
Humidity fluctuation ≤2.5%
Temperature deviation ≤±2.0℃
Humidity Deviation ≤±3%
Heating Rate ≧2-3°C/min
Cooling Rate ≧1°C/min, average no load
Load condition None
Working noise

A sound level≤70dB(A)

(Measured in a soundproof room with an ambient temperature of 25°C and low echo. Using A weighting, test the average of 9 points. Each test point is 1 meter away from the noise source horizontally and 1 meter above the ground.)

 
c) Controller specifications

Technical indicators:

1. 7-inch color touch screen

2. Two control modes: program/fixed value

3. Sensor type: two PT100 inputs (electronic sensor input optional)

4. Output mode: voltage pulse (SSR)/control output: 2 (temperature/humidity)/2 4-20mA analog output/16 relay outputs (passive)

5. Control signal: 8 IS control signals/8 T control signals/4 AL control signals

6. Alarm signal: 16 DI external obstacle alarms

7. Temperature measurement range: -90.00℃--200.00℃, (optional -90.00℃--300.00℃) error ±0.2℃

8. Humidity measurement range: 1.0%--100%RH, error ±1%RH

9. Communication interface: (RS232/RS485, maximum communication distance 1.2km [optical fiber up to 30km])

10. Interface language type: Chinese/English

11. Equipped with English input function

12. Can be used with a printer (USB function optional)

13. A variety of signal combination relay outputs, and the signals can be subjected to logical operations (NOT, AND, OR, NOR, XOR), referred to as PLC programming ability

14. Diversified relay control methods: parameter->relay mode, relay->parameter mode, logic combination mode, composite signal mode

15. Program editing: 120 groups of programs can be programmed, and each group of programs can program up to 100 segments

 

 

 
Cooling system
Operation mode Air-cooled mechanical compression single-stage refrigeration mode
Heating and cooling devices

1. Hitachi or Emerson low-temperature and low-noise scroll compressor (air-cooled heat dissipation method).

2. Cooling method: air cooling

Heat and cold exchange device Single-stage refrigeration system, Emerson low-temperature and low-noise scroll compressor imported from the United States. Adopting ultra-high-efficiency SWEP cold coal heat and cold exchange design [made in Sweden (sus#316)], it is more efficient than the traditional internal spiral type.
Heating load adjustment

1. The automatic adjustment of the cold coal flow rate device is adopted to effectively take away the heating load of the product to be tested, which is synchronized with German/Japanese technology.

2. Compared with traditional designs, the control stability and reproducibility are higher, and it achieves ultra-high performance in terms of power saving and energy saving.

Refrigeration compressor

Hitachi or Emerson low temperature and low noise scroll compressor

 

 
 
 
Details

 

Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78 0Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78 1