UL 1642 Temperature Controlled Type External Short Circuit Tester 500A
Complied Standards & Clauses
It is conforms to the standard of IEC 60335-1:2021 Annex B, UN38.3 clause 4.5 Test T.5, UL 1642, IEC 62619:2017 clause 7.2.1, IEC62133-1:2017 clause 7.3.2 , IEC62133-2:2017 clause 7.3.1 and 7.3.2 , IEC62133:2014 clause 7.3.2,8.3.1, 8.3.2, IEC60086-4 clause 6.5.1, IEC60086-4 clause 6.5.8 6.5.9 , and so on .
Equipment overview
Temperature control:
Normal temperature RT+10℃~100℃ (can be preset)
Temperature rise rate 3℃/min
Temperature dial 0.5℃
Temperature uniformity: ±2℃
Basic performance:
1: Simple operation and control: touch screen human-machine interface, touch editing control; the battery is placed on the shelf of the thermostat. Close the door and press the touch screen test button to automatically complete the test.
2: Safety and explosion-proof: The inner and outer boxes have been strengthened in design.
3: Overall aesthetic design: beautiful and elegant appearance.
4: Convenient to move into position: The bottom of the equipment is designed with universal wheels and leveling feet to facilitate the movement and fixation of the equipment.
Technical Parameters
Model | SN551-125L500A | |
Max. load current | 500A | |
DC response time | ≤5μs | |
Built-in resistor | 9±1mΩ | |
Inner chamber size | W500*500H*D500mm | |
Control method | PLC and Touch screen | |
Inner chamber material | Stainless steel | |
Sealing strip | Corrosion-resistant silicone. | |
Temperature control |
Normal temperature RT+10℃~100℃ (can be preset) Temperature rise rate 3℃/min Temperature dial 0.5℃ Temperature uniformity: ±2℃ |
|
Test stop condition |
1) The battery temperature drops to 20% lower than the peak; 2) Short circuit time |
|
Battery surface temperature | Can monitor temperature changes during battery surface testing | |
Sample rack | Stainless steel SUS #201 perforated steel plate storage rack, with a maximum load-bearing capacity of 30KG on a single layer. The height is adjustable at the same time. | ![]() |
Hall element collects current signal |
Hall elements are used to collect the current generated when the short-circuit system is short-circuited, avoiding the generation of contact resistance, and the data transmission is stable and accurate;
|
![]() |
Lead hole | There is a lead hole with a diameter of 50mm on the left side of the box for test wires to pass through. |
|
Chamber door |
High-strength hinges are used to fix the door, and at least 2 sets of explosion-proof locks can be installed on the door to fix it.
|
![]() |
Explosion-proof pressure relief device | It has the function of exhaust, explosion-proof and pressure relief. The rear of the protective box has a magnet-adsorbed pressure relief door (200*200mm). When strong airflow impacts, the pressure relief door automatically opens and closes to reduce the impact of the explosion. |
|
Lighting | The test chamber door is designed with high-brightness LED lighting to make it easy to see the test conditions in the test chamber. | ![]() |