logo

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Walk In Environmental Test Chamber
Created with Pixso.

Climatic Test Chamber Environmental Walk-in Temperature And Humidity Test Chamber 48m³

Climatic Test Chamber Environmental Walk-in Temperature And Humidity Test Chamber 48m³

Brand Name: Sinuo
Model Number: SN886-48m³
MOQ: 1
Payment Terms: T/T
Supply Ability: 10 Sets Per Month
Detail Information
Place of Origin:
China
Certification:
Calibration Certificate (Cost Additional)
Effective Volume:
48m3
Temperature Range:
-30℃~+60℃
Humidity Fluctuation:
≤±2.0%R.H
Humidity Range:
20%〜98%RH
Heating Rate:
-30℃~+60℃ About 2~3℃/min
Cooling Rate:
+60℃~-30℃ About 0.7~1℃/min
External Dimensions Approx.:
4250 Mm*3580 Mm*5200 Mm(W*H*D)
Inner Box Dimensions:
4000 Mm*3000 Mm*4000mm(W*H*D)
Packaging Details:
Export packing
Supply Ability:
10 Sets Per Month
Highlight:

48m3 Walk In Environmental Test Chamber

,

Walk In Climatic Test Chamber

Product Description


 

Climatic Test Chamber Environmental Walk-in Temperature and Humidity Test Chamber 48m³

 

Complied Standards & Clauses


 

Conforms to:

IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”


Product Overview


 

The walk-in constant temperature and humidity test room is suitable for safety performance testing, reliability testing, product screening testing, etc. of electronic components. At the same time, through these tests, the reliability of the product is improved and the quality control of the product is carried out.

The walk-in constant temperature and humidity test room is an essential test equipment in the fields of aviation, automobiles, home appliances, scientific research, etc. Sample range: electrical, electronic, semiconductor, communication, optoelectronics, electrical appliances, automotive electrical appliances, materials and other products. This equipment is used to assess and determine the parameters, performance, and adaptability of the above samples after the high and low temperature and humidity tests with rapid changes in temperature environment.

It is suitable for schools, factories, military industry, research and development and other units.

 

Technical Parameters


 

Volume and Size
Effective volume 48m3
Inner box dimensions

W:4000 mm

H: 3000 mm

D: 4000 mm

External dimensions Approx.

W: 4250 mm

H: 3580 mm

D: 5200 mm

 
 
Performance (ambient temperature -5℃~+28℃, no-load condition)
Temperature range -30℃~+60℃
Heating rate -30℃~+60℃ About 2~3℃/min (no load, average)
Cooling rate  +60℃~-30℃ About 0.7~1℃/min(no load, average)
Resolution accuracy 0.01℃ Data measured under no-load conditions
Temperature fluctuation ±0.5℃
Temperature deviation ±2.0℃
Humidity range 20%~98%RH
Humidity deviation

Below 75%RH: ≤±5.0%RH

Above 75%RH: ≤+2/-3%R.H

Humidity fluctuation ≤±2.0%R.H
 Temperature and humidity control capability range diagram Climatic Test Chamber Environmental Walk-in Temperature And Humidity Test Chamber 48m³ 0
Load conditions Allow max. 4KW calorific value during testing
Power source for UUT

Climatic Test Chamber Environmental Walk-in Temperature And Humidity Test Chamber 48m³ 1

Climatic Test Chamber Environmental Walk-in Temperature And Humidity Test Chamber 48m³ 2

 

Power supply AC3¢5W 380V 60Hz (R, STN three-phase five-wire plus ground wire) (voltage fluctuation ≤ ±10%)
Power The total power of the equipment is about 45KW
Noise Measured according to GB/T14623-2008, the noise level is ≤75dB (the noise detection device is measured at a distance of 1m from the equipment door).
Standards

IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”

 

Details


 

Climatic Test Chamber Environmental Walk-in Temperature And Humidity Test Chamber 48m³ 3Climatic Test Chamber Environmental Walk-in Temperature And Humidity Test Chamber 48m³ 4