Brand Name: | Sinuo |
Model Number: | SN8810C-1m³ |
MOQ: | 1 |
Price: | Customized |
Payment Terms: | T/T |
Supply Ability: | 30 sets/month |
ISO 16750-4 Salt Spray Chamber Compound Salt Spray Test Chamber
Complied Standards & Clauses
It can meet the national standard ISO 16750-4: 2006 Road vehicles Environmental conditions and tests for electrical and electronic equipment Part 4: Climatic loads clause 5.5 salt spray test.
Equipment Overview
The equipment has an emergency braking function, and a brake switch is installed on the equipment. When an abnormal situation occurs, the equipment can be powered off through the control switch.
The equipment is equipped with corresponding system software, which can run stably on the provided operating system, and the software interface is in Chinese or English, the software includes temperature change test, humidity, precision calibration, and equipment self-test module.
The system software can record in real time, save automatically, and optimize data, and can draw temperature-time, humidity-time curves through software settings.
The system software is set with a safety protection parameter interface, and after the setting is completed, it will be given priority during the test process, thereby ensuring the safety of the test.
Technical Parameters
Product Name |
Compound Salt Spray Test Chamber |
Product model | SN8810C-1m³ |
Nominal internal volume |
1m³ |
Effective size of inner box (mm) |
1000×1000×1000 W×D×H |
External space (mm) | About 1600×2400×2000 W×D×H |
Weight | About 500kg |
Bearing capacity | About 80KG |
Control accuracy |
Temperature resolution: 0.1°C Humidity resolution: 0.1%R.H Temperature deviation: ±2.0℃ Humidity deviation: ≤+2-3%R.H when ≥75%RH, humidity deviation: ≤±5%R.H when <75%RH Temperature fluctuation: ±1℃ Humidity fluctuation: ±3%R.H Note: The temperature uniformity and deviation are measured under the conditions of ambient temperature +25°C, relative humidity ≤85% RH, and no sample. |
Heating rate of the test room | RT→+60℃≤45 min |
Heating rate of saturated tank | RT→+65℃≤45 min |
Specimen restrictions |
This test chamber prohibits: Testing or storage of samples of flammable, explosive and volatile substances Testing or storage of samples of corrosive substances Testing or storage of biological samples Testing or storage of samples of strong electromagnetic emission sources Testing and storage of radioactive material samples Testing and storage of samples of highly toxic substances Testing and storage of samples that may produce highly toxic substances during testing or storage |