| Brand Name: | Sinuo |
| Model Number: | SN7711 |
| MOQ: | 1 |
| Price: | Customized |
| Payment Terms: | T/T |
| Supply Ability: | 10 Sets Per Month |
This flammability test chamber is fully compliant with UL 1581 and UL 94 flame test standards. It simulates the effects of flame exposure on electrical and electronic products in the early stages of a fire, enabling accurate assessment of fire hazards.
It is designed for testing finished wires, cables, and cords, supporting key tests including the 1080 VW-1 vertical specimen flame test and 1100 horizontal specimen / FT2 flame test. These tests evaluate the ability of wires, cables, and flexible cords to resist flame spread to adjacent flammable materials during combustion.
The equipment is built with a PLC control system and an intuitive touchscreen interface for humanized operation. It features a black background and multi-function flame gauge, a durable stainless steel chamber body, and a large observation window for clear visibility. The original imported flame control system simplifies flame adjustment, delivering stable performance and convenient operation.
| Complied standard | UL1581, UL94 |
| Power supply | Two-phase 220V/ 60Hz |
| Operation system | Mitsubishi PLC control, VEINVIEW7” touch screen |
| Ignition Process | Automatic |
| Burner |
Diameter: 9.5mm ± 0.5mm Length:100mm Original imported, compliant with ASTM 5025 standard |
| Standard power |
50W&225W&500W: 1. 225W horizontal burning test for UL1581 2. 500W vertical burning test for UL1581 3. 50W horizontal burning test for UL94 4. 50W vertical burning test for UL94 5. 500W horizontal burning test for UL94 6. 500W vertical burning test for UL94 |
| Burning Angles | 0°, 20°, 45° adjustable |
| Flame Height | 20mm~125mm±1mm adjustable |
| Timing Device | Presettable up to 9999X0.1s |
| Thermocouple |
Total 2 pcs attached to copper blocks U.S. original Omega Φ0.5mm armored stainless steel sheathed K-type thermocouple |
| Temperature Measurement Distance |
UL 1581: 225W:25±1mm; 500W: 55±1mm UL94: 50W: 10±1 mm; 500W: 55±1 mm |
| Temperature Measurement Range | MAX 1100°C |
|
Gas flow |
Equipped with an original imported flowmeter, with adjustable flow rate and accuracy of 1%. Reference values for each test are as follows: UL1581 (power, flame height, temperature measurement time and flow): -225W: (16.5mm), 84±2S, 405 ±10mL/min -500W: Inner flame:40±2mm & Outer flame:125±10mm, 54±2S, 965 ±30mL/min UL 94 (power, flame height, temperature measurement time and flow): -50W: 20±2mm(there is no internal and external flame), 44±2S , 105±5ml/min -500W:Inner flame:40±2mm & Outer flame:125±10mm, 54±2S, 965±30ml/min |
|
Copper Weight |
Total 2 pcs of copper block and attached with thermocouples: -50W:Ф5.5mm±0.01mm,weight before drilling 1.76 ± 0 .01 g -225W & 500W:Ф9mm±0.01mm,weight before drilling 10 ± 0 .05g Copper head, Cu-ETP purity:99.96%, |
| Gas Category | Methane |
| Test Space | 4m³ |
| Chamber and Appearance | Stainless steel chamber, black matt background with exhaust fan |
| Size and weight |
Dimensions: W*D*H=1.7*1.3*2.4m Weight: approx. 350kg |